Model
|
MS-60-12
|
MS-60-15
|
MS-60-24
|
DC Voltage
|
12V
|
15V
|
24V
|
Rated Current
|
5A
|
4A
|
2.5A
|
Current Range
|
0 ~ 5A
|
0 ~ 4A
|
0 ~ 2.5A
|
Rated Power
|
60W
|
60W
|
60W
|
Ripple & Noise
|
120mVp-p
|
150mVp-p
|
200mVp-p
|
Voltage Adj. Range
|
10.8 ~ 13.2V
|
13.5 ~ 16.5V
|
21.6 ~ 26.4V
|
Voltage Tolerance
|
±1.0%
|
±1.0%
|
±1.0%
|
Line Regulation
|
±0.5%
|
±0.5%
|
±0.5%
|
Load Regulation
|
±0.5%
|
±0.5%
|
±0.5%
|
Setup, Rise Time
|
500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
|
Hold Up Time
|
50ms/230VAC 10ms/115VAC at full load
|
|
|
INPUT
|
|
Voltage Range
|
AC 86~264VAC 47~63 Hz;DC 240~370VDC
|
Frequency Range
|
47 ~ 63Hz
|
Efficiency
|
82%
|
82%
|
84%
|
AC Current
|
1.5A/115VAC 0.9A/230VAC
|
Inrush Current
|
Cold Start 45A
|
Leakage Current
|
<2mA / 240VAC
|
|
|
PROTECTION
|
|
Over Load
|
110 ~ 150% rated output power
|
Protection type: Hiccup mode, recovers automatically after fault condition is removed
|
|
|
ENVIRONMENT
|
|
Working Temp.
|
-20 ~ +60°C (Refer to “Derating Curve”)
|
Working Humidity
|
20 ~ 90% RH non-condensing
|
Storage Temp., Humidity
|
-40 ~ +85°C, 10 ~ 95% RH
|
Temp. Coefficient
|
±0.03%/°C (0 ~ 45°C)
|
Vibration
|
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
|
|
SAFETY & EMC
|
|
Safety Standards
|
Design refer to UL1012
|
EMC Emission
|
Design refer to EN55022 CLASS A
|
|
|
OTHERS
|
|
Dimension
|
99*97*36mm (L*W*H)
|
Weight
|
0.40 Kg
|
Packing
|
60pcs/carton
|
|