Model |
S-35-5 |
S-35-12 |
S-35-15 |
S-35-24 |
Output |
DC Voltage |
5V |
12V |
15V |
24V |
Rated Current |
7A |
3A |
2.4A |
1.5A |
Current Range |
0~7A |
0~3A |
0~2.4A |
0~1.5A |
Rated Power |
35W |
36W |
36W |
36W |
Ripple & Noise (max.) Note.2 |
75mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
Voltage Adj. Range |
4.75~5.5V |
10.8~13.2V |
13.5~16.5V |
21.6~26.4V |
Voltage Tolerance Note.3 |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load Regulation |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
Setup,Rise, Hold time |
200ms, 100ms, 30ms at full load |
Input |
Voltage Range |
85 ~ 132VAC / 170 ~ 264VAC selected by switch 240 ~ 370VDC |
Frequency Range |
47~63HZ |
Efficiency(Typ.) |
70% |
76% |
78% |
78% |
AC Current |
0.8A/115VAC 0.45A/230VAC |
Inrush Current (max.) |
COLD START 18A/115VAC 36A/230VAC |
Leakage Current |
<2mA / 240VAC |
Protection |
Over Load |
105 ~ 150% rated output power |
Protection type : Fold back current limiting, recovers automatically after fault condition is removed |
Environment |
Working Temperature |
-10 ~ +60°c (Refer to output load derating curve) |
Working Humidity |
20~90% RH Non-condensing |
Storage temp.& humidity |
-20~+85°C, 10~95%RH |
Temp. coefficient |
±0.03%/°C (0~50°C) |
Vibration |
10 ~ 500Hz, 2G 10min./1 cycle,60min.each along X,Y,Z axes |
Safety & EMC
(Note 4.)
|
Safety Standards |
Design refer to UL1012 |
Withstand Voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
EMI Conduction & Radiation |
Design refer to FCC Part15 J Conduction Class B |
Others |
MTBF |
435.2K hrs min. MIL-HDBK-217F (25°c ) |
Dimension |
129*98*38mm (L*W*H) |
Packing |
0.41Kg; 30pcs/13.4Kg/0.86CUFT |
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. |
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. |
3. Tolerance : includes set up tolerance, line regulation and load regulation. |