MODEL |
|
|
S-1200-12 |
S-1200-15 |
S-1200-24 |
S-1200-48 |
OUTPUT |
DC VOLTAGE |
|
|
12V |
15V |
24V |
48V |
VOLTAGE TOLERANCE |
|
|
± 1% |
± 1% |
± 1% |
± 1% |
RATED CURRENT |
|
|
100A |
80A |
50A |
25A |
CURRENT RANGE |
|
|
0-10A |
0-8A |
0-5A |
0-2.5A |
RATED POWER |
120W |
120W |
1200W |
1200W |
1200W |
1200W |
RIPPLE & NOISE(MAX) |
80mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
DC VOLTAGE
ADJUSTMENT RANGE |
± 10% |
± 10% |
± 10% |
± 10% |
± 10% |
± 10% |
SETUP, RISE, HOLD UP TIME |
200ms, 100ms, 20ms |
INPUT |
VOLTAGE RANGE |
85~132/170~264VAC Selected by Switch, 47~63Hz |
AC CURRENT |
3.2A/115 V 1.6A/ 230 V |
EFFICIENCY |
78% |
80% |
82% |
82% |
84% |
84% |
INRUSH CURRENT |
Cold start 17A/115V 35A/230V |
LEAKAGE CURRENT |
< 1 mA/240VAC |
PROTECTION |
OVERLOAD PROTECTION |
135%~165% Shut down O/P voltage, re-power on to recover |
OVER-VOLTAGE PROTECTION |
^ ^ |
HIGH TEMPERATURE PROTECTON |
^ ^ |
ENVIRONMENT |
WORKING TEMP. & HUMIDITY |
-10º C~+50º C; 20%~90 %RH |
STORAGE TEMP. & HUMIDITY |
-20º C~+85º C; 10%~95 %RH |
VIBRATION |
10~500Hz, 2G 10min. /1 cycle, period for 60min, each along X. Y. Z axes |
SAFETY |
WITHSTAND VOLTAGE |
I/P-O/P: 1.5KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
ISOLATION RESISTANGE |
I/P-O/P, I/P-FG, O/P-FG: 500VDC/100MΩ |
STANDARDS |
SAFETY STANDARDS |
Design refer to UL1012 |
EMC STANDARDS |
Design refer to EN55022, EN55024, EN61000 |
OTHERS |
WEIGHT |
2.5Kg |
PACKING |
4pcs/ 12Kg |
NOTE |
1. Tolerance: Includes set up tolerance, line regulation and load regulation.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire teminated with a 0.1μ f & 47μ f parallel capacitor. |