Model |
S-145-5 |
S-145-7.5 |
S-145-12 |
S-145-15 |
S-145-24 |
Output |
DC Voltage |
5V |
7.5V |
12V |
15V |
24V |
Rated Current |
25A |
18A |
12A |
9.6A |
6A |
Current Range |
0 ~ 25A(30A max.) |
0 ~ 18A(21A max.) |
0 ~ 12A(14A max.) |
0 ~ 9.6A(11A max.) |
0 ~ 6A(7A max.) |
Rated Power |
125W |
135W |
144W |
144W |
144W |
Ripple & Noise (max.) Note.2 |
100mVp-p |
120mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
Voltage Adj. Range |
4.5 ~ 5.5V |
6~8.3V |
10.6~13.2V |
13.5~16.5V |
21~28V |
Voltage Tolerance Note.3 |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Setup,Rise, Hold time |
100ms, 50ms, 20ms at full load |
Input |
Voltage Range |
88 ~ 132VAC/176 ~ 264VAC selected by switch |
Frequency Range |
47~63HZ |
Efficiency(Typ.) |
78% |
80.5% |
80.5% |
81% |
83.5% |
AC Current |
3.2A/115VAC 1.6A/230VAC |
Inrush Current (max.) |
COLD START 35A |
Leakage Current |
<3.5mA / 240VAC |
Protection |
Over Load |
125 ~ 165% rated output power |
Protection type : Shut down o/p voltage, re-power on to recover |
Over Voltage |
5.6 ~ 6.8V |
8.6 ~ 10V |
13.8V~16.2V |
17.3V~20.3V |
29V~32V |
Protection type : Shut down o/p voltage, re-power on to recover |
Environment |
Working Temperature |
-10 ~ +60°c (Refer to output load derating curve) |
Working Humidity |
20~90% RH Non-condensing |
Storage temp.& humidity |
-20~+85°C, 10~95%RH |
Temp. coefficient |
±0.03%/°C (0~50°C) |
Vibration |
10 ~ 500Hz, 2G 10min./1 cycle,60min.each along X,Y,Z axes |
Safety & EMC
(Note 4.)
|
Safety Standards |
Design refer to UL1012 |
Withstand Voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
EMI Conduction & Radiation |
Compliance to EN55022 (CISPR22) Class B |
EMS IMMUNITY |
Compliance to IEC801-2,3,4 Light industry level, criteria A |
Others |
MTBF |
286.7K hrs min. MIL-HDBK-217F (25°c ) |
Dimension |
199*98*38mm (L*W*H) |
Packing |
0.71Kg; 30pcs/22.5Kg/1.22CUFT |
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°c of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. C3,4,22,41,63,140,141 must be removed.
5. Refer to output derating curve us input voltage.
|